MOXA IOLOGIK E1212

Modified on Wed, 11 May, 2022 at 12:03 PM

This page provides detailed information about the MOXA e1212 that comes pre-installed in the Sawyer Controller. 


Contents


Introduction


The Sawyer robot controller uses a Moxa ioLogik E1212 Remote Terminal Unit for interfacing with the external world. This unit has been preconfigured to work out-of-the-box with the Intera software and shows up as the “Robot” device when configuring signals on a task. 


Specifications


  • Digital Inputs (8 Channels)
    • Sensor Type: Wet Contact (NPN or PNP), Dry Contact
    • I/O Mode: DI or Event Counter
    • Dry Contact:
      • On: short to GND
      • Off: open
    • Wet Contact (DI to COM):
      • On: 10 to 30 VDC
      • Off: 0 to 3 VDC
  • Digital Output (8 Channels)
    • Type: Sink
    • I/O Mode: DO or Pulse Output
    • Pulse Output Frequency: 500Hz
    • Over-Voltage Protection: 45VDC
    • Over-Current Protection: 2.6A (4 channels @ 65 mA)
    • Over-Temperature Shutdown: 175°C (typcial), 150°C (min.)
    • Current Rating: 200 mA per channel

Physical Characteristics


Wiring: I/O cable max. 14 AWG


Environmental Limits


Operating Temperature: -10 to 60°C (14 to 140°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Altitude: Up to 2000 m 


Standards and Certifications


Safety: UL 508 EMI: EN 55022; EN 61000-3-2; EN 61000-3-3; FCC Part 15, Subpart B, Class A EMS: EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Green Product: RoHS, CRoHS, WEEE Hazardous Location: UL/cUL Class I Division 2, ATEX Zone 2 


I/O Wiring Diagram


ATTENTION Determine the maximum possible current for each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current exceeds the maximum rating, the wiring could overheat, causing serious damage to your equipment. For safety reasons, we recommend an average cable size of 22 AWG. However, depending on the current load, you may want to adjust your cable size (the maximum wire size for power connectors is 2 mm). 


Inputs


The inputs belong on channels DI0-DI7. Please follow the diagram below in order to understand how to connect an input device into the Moxa ioLogik E1212 device: 



A Dry Contact is a contact that does not provide voltage.

A Wet Contact is a contact that will provide voltage when closed.


Outputs


The outputs belong on channels DIO0-DIO7. Please follow the diagram below in order to understand how to connect an output device into the Moxa ioLogik E1212 device: 


Note: A "load" in a circuit schematic is a component or portion of the circuit that consumes electrical power. For the diagrams shown in this document, "load" refers to the devices or systems connected to the I/O unit.

IP Address


For instructions on how to configure the IP address of the MOXA via the web console, see MOXA E1212 user manual.

IP: 203.0.113.129

Subnet Mask: 255.255.255.0

Gateway: 203.0.113.1